Case Studies
1. Project Overview

| Item | Content |
|---|---|
| Project Name | Haikou Citizen & Tourism Center |
| Application Field | Sub-segments: Wood + Sealant |
| Products Used | INGADA MS-625 — Low-Modulus Polyether Sealant, ±25% movement, French A+ (Roof / Façade / External Joints) INGADA MS-77 — Premium Phthalate-Free Flooring Adhesive, ΔLw ≥16 dB, 0 phthalate, LEED-compliant (Wood Floor & Interior Wood Decoration) INGADA MS-35 — Instant Bond Construction Adhesive, 800 kg/m² grab, 3.2 MPa shear (Wood-Metal & Wood-Glass Positioning) INGADA MS-50A — High-Hardness Anti-Mold Sealant, Shore A ≥80, ceramic-grade gloss (Kitchen / Washroom / Wet Areas) |
| Project Location | BinHai Park, Haikou, Hainan Province, China |
INGADA’s Role: INGADA supplied a Wood + Sealant MS Polymer + Silicone package — MS-625 (±25% movement, 0.4 MPa modulus, French A+) for the 9,001 m² timber roof and façade joints, MS-77 (0 phthalate, ΔLw ≥16 dB) for interior wood flooring and decoration, MS-35 (800 kg/m² grab, 3.2 MPa shear) for V-column-to-glulam-beam and glass-to-timber positioning, and MS-50A (Shore A ≥80 anti-mold) for kitchens & washrooms — to Asia’s largest pure-wood roof in Hainan’s tropical coastal climate, supporting the project’s green-building-3-star IAQ and a 30–50-year design life of the red-cedar shingle skin.




2. Engineering Challenge
Challenge 1 — Hainan Tropical Coastal Climate on a 9,001 m² Pure-Wood Roof
Details
Haikou is a tropical-monsoon coastal city: annual rainfall ≈ 1,600 mm, average relative humidity ≈ 80%+, average annual sunshine ≈ 2,000 hours, and regular typhoon exposure. The roof comprises three pure-wood glulam shells — supported by V-shaped steel columns — clad with 350,000 pieces of 30+ mm-thick Canadian red-cedar shingles fastened with 1.4 million steel nails (per official Haikou government release). Every shingle overlap, every shingle-to-batten seam, every batten-to-glulam-beam interface is a permanent water-ingress point that must be sealed against driving tropical rain, salt-spray corrosion, and 3,000+ hours/year of UV — without trapping moisture that would rot the cedar.
Challenge 2 — Wood · Steel · Glass · Volcanic-Stone Multi-Substrate Joint Sealing
Details
Four materials with very different thermal-expansion coefficients meet at almost every joint of this building: timber (≈ 3–5 × 10⁻⁶/K along the grain, 30–60 × 10⁻⁶/K across the grain), V-shaped steel columns (≈ 12 × 10⁻⁶/K), glass curtain wall (≈ 8.5 × 10⁻⁶/K), and volcanic-stone (basalt) wall (≈ 10 × 10⁻⁶/K). Every V-column-to-glulam-beam head, every wood-roof-to-glass-curtain-wall termination, and every timber-deck-to-volcanic-stone-retaining-wall transition has to absorb unequal daily thermal movement without tearing the joint — a hard sealant will simply delaminate inside 1–2 tropical seasons.
Challenge 3 — Fire · Mold · IAQ: Three Conflicting Mandates on a “Breathing” Wood + Stone Building
Details
Three sustainability mandates collide: (a) the timber roof must meet Chinese code-required structural-fire-resistance (timber char-layer is part of the design, but every fastener and joint must be sealed so char does not propagate); (b) the wet areas (kitchens, washrooms, F&B back-of-house) and the park-side coffee bar must stay mold-free under 80%+ RH — but a hard silicone will crack and a soft acrylic will feed mold; (c) the volcanic-stone wall is designed to “breathe” — its open-pore basalt naturally regulates indoor humidity — so the perimeter joint around it must not be a hermetic air barrier, or the wall loses its IAQ function. The sealing system therefore has to be low-VOC (French A+), Shore A ≥80 in wet zones, yet elastic enough at the stone perimeter to let the wall breathe.
3. INGADA Solution
| Challenge | Product | One-line Key Advantage |
|---|---|---|
| Roof waterproofing, façade & external joint sealing, multi-substrate thermal-movement absorption (Challenge 1 & 2) | MS-625 Low-Modulus Polyether Sealant | ±25% movement capacity · Ultra-low modulus 0.4 MPa · -40°C to 90°C · 3,000-hour UV resistance · French A+ certified · “breathes” with timber instead of cracking it (per official product page) |
| Wood-to-metal and wood-to-glass instant positioning (V-column head, glass-curtain-wall-to-timber termination) (Challenge 2) | MS-35 Instant Bond Construction Adhesive | 800 kg/m² instant grab · 3.2 MPa shear strength · 0-sag vertical bonding · -30°C to 100°C · “no drill, no clamp” heavy-material support-free bonding — perfect for the heavy V-column heads and curved glulam-beam connections on site (per official product page) |
| Interior solid-wood / engineered-wood floor and timber decoration — needs elastic bonding with IAQ grade and acoustic dampening (Challenge 2 & 3) | MS-77 Premium Phthalate-Free Flooring Adhesive | 0 phthalate · Load capacity ≤15 kg/cm² · Acoustic ΔLw ≥16 dB · French A+ / FDA / LEED compliant · 100% solvent-free · designed for direct-stuck solid wood & engineered wood on tropical substrates (per official product page) |
| Kitchen / washroom / wet-area mold-proof sealing (Challenge 3) | MS-50A High-Hardness Anti-Mold Sealant | Shore A ≥80 ceramic-grade gloss · behaves like a “hygienic shield” solid-ceramic joint · eliminates mold risk in food-prep / wet areas where standard sealants fail and peel under constant cleaning (per official product page) |
5. Project Data
| 📦 Supply Volume: ≈3 tons | ≈3 tons |
| 📐 Application Area | Roof 9,001 m² (pure-wood, 3 shells) · Total building ≈ 29,800 m² (excl. wood roof) · Site ≈ 39,192 m² |
| 🛡️ Performance Warranty | design life 20–30 years |
| ⏱️ Construction Time Saved | 20% (qualitative: MS-35’s 800 kg/m² instant grab eliminates temporary clamping on the heavy glulam-beam × V-column-head connections; MS-77’s direct-stuck wood-floor system skips nail-down steps) |
Discover more from INGADA The Ultimate Bonding Expert
Subscribe to get the latest posts sent to your email.